Refrigeration Air conditioning Pictures

  • Home
  • Refrigeration Air conditioning Pictures

Refrigeration Air conditioning     Pictures Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from Refrigeration Air conditioning Pictures, Media, Tarbella Dam, .

09/11/2020

Brand Problem Problem Display
Samsung E464 IPM Over Current overload
Samsung E461 compressornot start
Samsung E473 compressor blocking
Samsung E466 DC Link cardvoltage error
Samsung E221 outdoor temp. sensor
Samsung E416 Discharge Temp. Overheat
Samsung E251 Dischargetemp. sensor
Samsung E468 electric current sensor
Samsung E465 compressor error
Samsung E237 winding error of the temp. sensor
Samsung E202 connection time (1 minute) expired
Samsung E458 Fan Error(Outdoor)
Samsung E471 OTP error
Samsung E467 Compressor rotation/Wire Missing
Samsung E440 operation condition secession Low
Samsung E441 operation condition secession High
Samsung E469 DC error of the voltage sensor
Samsung E462 Trip error / PFC Over current
Samsung E554 leak of refrigerant
Samsung E472 zero crossing of the AC voltage
Samsung E556 Capacity Miss-match
Samsung E121 internal air temp. sensor is closed / cut off
Samsung E122 evaporator temp. sensorclosed / cut off
Samsung E154 Indoor unit fan error
Samsung E101 connection time (1 minute) exceeded
Samsung E186 MPI error
Samsung E101 Indoor TOOutdoor Wiring issuse
Samsung E102 Indoor TOOutdoor Wiring issuse
Samsung E121 ROOM Temp. sensor error
Samsung E122 INDOOR MID, INDOOR IN PIPE-Temp. sensor
Samsung E154 Fan Error (Indoor)
Samsung E162 EEPROM(Indoor motor)
Samsung E231 Cond Temp. Sensor
Samsung E422 EEV or Valve Close error-Self diagnosis
Samsung E470 EEPROM Data Error (no data)
Samsung E471 EEPROM Data Error (Main Micom Inv Micom)
Samsung E474 Heatsink Sensor Error
Samsung E483 Over Voltage Protection
Samsung E484 PFC Over Load
Samsung E485 Input Current Sensor
Samsung E488 AC Input Voltage Sensor
Samsung E500 Heatsink Over Temperature Error
Samsung E554 Gas Leak Error
Samsung E163 Option Error
Samsung E203 Time out Comm. (Inv Micom Main Micom)
Samsung E440 over(Heating) Error
Samsung E441 Prohibit Operation Condition Error (Cooling)
LG C1 or CH1 Indoor temperature sensor open or closed circuit.

48):-Compraser ke hisab se Condenser ke liye pipe
05/10/2020

48):-
Compraser ke hisab se Condenser ke liye pipe

47):-Ak Harss power  ma 746 Watt hotey Hain
05/10/2020

47):-
Ak Harss power ma 746 Watt hotey Hain

46):-Denfast Compraser ka Size
05/10/2020

46):-
Denfast Compraser ka Size

45):-Air Conditioning Duwall Capister Tarminal Maloom karna
05/10/2020

45):-
Air Conditioning Duwall Capister Tarminal Maloom karna

44):-Air Conditioning Tools
05/10/2020

44):-
Air Conditioning Tools

43):-Full Form of Short Answer
05/10/2020

43):-
Full Form of Short Answer

42):-Split ac ERORR Coads
05/10/2020

42):-
Split ac ERORR Coads

41):-National Compraser Sizes
28/08/2020

41):-
National Compraser Sizes

40):-Revarsing valoo use
28/04/2020

40):-
Revarsing valoo use

39:-Revarsing valo
28/04/2020

39:-
Revarsing valo

38):-ابزارپش سٹم
28/04/2020

38):-
ابزارپش سٹم

37):-Card coller and card ki tabdeli
22/04/2020

37):-
Card coller and card ki tabdeli

36):-Dobbel door refregraion wiring dygram
22/04/2020

36):-
Dobbel door refregraion wiring dygram

35):-Single door refregraion dygram
22/04/2020

35):-
Single door refregraion dygram

34):-Sereyoo ka sarket
22/04/2020

34):-
Sereyoo ka sarket

33):-Window  ac dygram
22/04/2020

33):-
Window ac dygram

32):-Copper  and silver wilding torch
22/04/2020

32):-
Copper and silver wilding torch

31):-Tangtester Meter
22/04/2020

31):-
Tangtester Meter

30):-Split ac indoor sarket
22/04/2020

30):-
Split ac indoor sarket

29):-Water cooler dygram
22/04/2020

29):-
Water cooler dygram

28):-Spilt out door dygram
22/04/2020

28):-
Spilt out door dygram

27):-Copister ko Cheek,charge,discharge karna
27/03/2020

27):-
Copister ko Cheek,charge,discharge karna

26):-No frost Fridge
27/03/2020

26):-
No frost Fridge

25):-Gass Wilding
27/03/2020

25):-
Gass Wilding

24):-Refregraion cycal
27/03/2020

24):-
Refregraion cycal

23):-Chiller Refregraion cykal dygram
27/03/2020

23):-
Chiller Refregraion cykal dygram

22):-Ghagg mani foldd
27/03/2020

22):-
Ghagg mani foldd

21):-Compraser ko Mukhtalif really ke madd se chalana
27/03/2020

21):-
Compraser ko Mukhtalif really ke madd se chalana

20):-Compraser prasher
27/03/2020

20):-
Compraser prasher

19):-Rac information
27/03/2020

19):-
Rac information

18):-National Compraser sizes
27/03/2020

18):-
National Compraser sizes

بزرگوں کے اقوال
26/03/2020

بزرگوں کے اقوال

17):-
26/03/2020

17):-

Islamic information
22/03/2020

Islamic information

16):-
21/03/2020

16):-

15):-
21/03/2020

15):-

14):-
21/03/2020

14):-

13):-
21/03/2020

13):-

12):-
21/03/2020

12):-

Address

Tarbella Dam

Telephone

03120518896

Website

Alerts

Be the first to know and let us send you an email when Refrigeration Air conditioning Pictures posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

  • Address
  • Telephone
  • Alerts
  • Claim ownership or report listing
  • Want your business to be the top-listed Media Company?

Share